Description
The CardioCare 2000 is an economically priced interpretive 12 channel electrocardiogram (ECG/EKG) machine that does not compromise on performance. Suitable for use in private practice, the ER, or hospitals. The CardioCare 2000 is designed for maximum ease of use and convenience.
Bionet Cardiocare 2000 12-Channel ECG Machine Feature:
- Simultaneous 12 Channel Resting ECG
- ECG Interpretation Program
- A4 Full-Size Paper
- Low Maintenance Cost
- ECG Filing System BMS-Plus
- Upgradeable Software
Product Specifications | Value |
---|---|
ECG Leads | Simultaneous 12 Leads Resting ECG |
Recording Channel | 3CH+1RHY, 6CH+1RHY, 12CH, 1CH Long Time (1min) |
Gain | 5, 10, 20, Auto (I~aVF: 10, V1~V6: 5) mm/mV |
Printing Speed | 12.5, 25, 50 mm/sec |
Sampling Rate |
Analysis Sampling Rate – 500sample/sec
Digital Sampling Rate – 8,000sample/sec |
Filters |
AC (50/60Hz, -20dB or better),
Muscle (25~35Hz, -3dB or better), Base Line Drift (off, 0.05, 0.1, 0.2Hz, -3dB or better), Low Pass Filter(off, 40Hz, 100Hz, 150Hz) |
Display |
2 x 16 Char LCD Display
Gain, Speed, Filter Status, HR, Printing Form, Rhythm Lead |
User Interface | Short Key |
Printer Resolution |
Thermal Print Head, Roll Paper
Report Paper • Width: A4/Letter – 215mm (8.5”) • Length: A4 – 297mm (11.7”) Letter – 279mm (11”) Resolution: 8dot/mm (0.125mm pitch) |
Patient data | ID, Name, Age, Gender, Height, Weight |
Basic Measurement | Heart rate(30~300bpm, ±3bpm), PR/RR int., QRS dur., QT/QTc int., P-R-T axis, SV1/RV5/R+S amp. |
Electrical |
Internal noise: 20uV(p-p)max
Input impedance: ≥ 50MΩ Input voltage range: ±5mV CMRR: > 105dB DC offset voltage: ≥ ±400mV Patient leakage current: < 10uA Frequency response: 0.05 ~ 150 with in –3dB Isolated , defibrillation and ESU protected |
Line Power |
Input: 100- 240Vac, 1.5-0.75A, 50-60Hz
Output: 15Vdc, 4.2A |
Battery type |
Replaceable and Rechargeable, Lithium ion, 11.1V, 2600mA
|
Battery Capacity | 6 hours of normal use or print 200 ECG pages(12 channel format at 25mm/s and 10mm/mV) Battery recharge to full capacity in 3hours. |
Communication | LAN |
Safety Conformity | Class I, Type CF Defibrillation-proof applied Part. |
Environmental Operation |
Ambient Temperature: 10~40℃
Relative Humidity: 30~85%RH Atmospheric Pressure: 70~106KPa |
Environmental Storage/Ship |
Ambient Temperature: -20~60℃
Relative Humidity: 10~95%RH Atmospheric Pressure: 50~106KPa |
Dimensions | 300(W) x 290(H) 95(H)mm, Approx. 3.0kg (Main Body) |
Standard Accessory |
Patient Cable (1 EA), Limbs Electrodes (1 SET),
Chest Electrodes (1 SET), ECG Paper (1 EA), Power Cord (1 EA) |
Options | Rechargeable Battery (1 EA), Cart(1 EA), Hanger (1 EA) |
List of Supply with ECG Machine :-
1. ECG Cable x1
2. Bulb Electrode x1
3. Clamp Electrode x1
4. Gel Bottle x1
5. Power Cable x1
6. Earthing Cable x1
7. User Manual x1
Reviews